Bioanalytical Biotransducers |
BB DEVICES |
Gold |
|
Biotin : Biotinylated surface |
BB Au-1050.5-FD-Biotin |
(for static cell) |
BB Au-1010.3-FD-Biotin |
(for flow through cell) |
|
Primary amine : Aminated surface-NH2 |
BB Au-1050.5-FD-NH2 |
(for static cell) |
BB Au-1010.3-FD-NH2 |
(for flow through cell) |
|
Carboxylic acid : COOH/COO- |
BB Au-1050.5-FD-COOH |
(for static cell) |
BB Au-1010.3-FD-COOH |
(for flow through cell) |
|
Hydroxyl : -OH- |
BB Au-1050.5-FD-OH |
(for static cell) |
BB Au-1010.3-FD-OH |
(for flow through cell) |
|
Sulfonate : -SO3H/-SO3 - |
BB Au-1050.5-FD-SO3- |
(for static cell) |
BB Au-1010.3-FD-SO3- |
(for flow through cell) |
|
Non-activated : No surface activation |
BB Au-1050.5-FD-X |
(for static cell) |
BB Au-1010.3-FD-X |
(for flow through cell) |
Introduction and Background
Applications of BBsApplications of BB in research and product development include:
Technical SpecificationsØ Chip Substrate: Schott D263 Borosilicate Glass Dielectric Constant, Epsilon(r) at 1 MHz = 6.7 Dielectric Loss Angle, tan delta, at 1 MHz = 61 x 10-4 Electrical Resistivity (50 Hz) (250 C) = 1.6 x 108 ohm cm Coefficient of Linear Thermal Expansion, * 20-300 = 7.2 x 10^-6 K^-1 Refractive Index at 20 C, ne ( Lambda = 546.1 nm) = 1.5249 Ø Metallization: 100 Å Ti / 1000 Å Au or Pt Digit length, d, (microns) = 4,985 No. of digit pairs per sensor, N = 50 Digit Width, a, (microns) = 10 Interdigit Space, a, (microns) = 10 Spatial Periodicity, lambda, (microns) = 40 Zaretsky Meander Length, M, (cm) = 24.93 cm Center Line or Serpentine Length (cm) = 49.55 cm Cell Constant (cm^-1) = 0.040 cm^-1 Ø IME Chip Dimensions (l x w x t) for the Un-packaged Die Monolithic, M = 1.75 x 1.00 x 0.05 Combined Differential, CD = 1.75 x 1.00 x 0.05 cm Full Differential, FD = 1.75 x 1.00 x 0.05 cm Electrode Body: Delrin Encapsulant: Epoxy header. Polyimide packaged chip. Leadwires: Color coded, 30AWG stranded copper, shielded, and PVC jacketed. MethodsChemoresistance responses of Bioanalytical Biotransducers may be obtained form a wide assortment of interrogation hardware. These fall into three categories.
Application NotesFor further information, request Application Notes or download files: IME1 - Interdigitated Microsensor Electrodes: Applications and References. IME2 - Conductimetric Urea Biosensor Formed From Interdigitated Microsensor Electrodes IME3 - Care and Cleaning Procedures
Contact:
Ann M. Wilson, Manager, |
||
News and Noteworthy || Company Profile || R & D Capabilities || Lab Products || Advanced Products || Company Directory || Personnel Bio's || Career Opportunities || Press Releases || Investor Relations || Related Links || Download Files || Price Lists |
||